管家婆免费资料大全

?
Jichai Huanneng > Products > Generator > Natural gas generator >
Natural gas generator (1200GF-T)
管家婆免费资料大全_Natural gas generator (1200GF-T)
MAIN SPECIFICATIONS OF GAS GENERATOR SET
Model 1200GF-T   Gas Engine Model H16V190ZLT-2
Rated power 1200kW/1500KVA   Alternator Siemens Series
Rated voltage 400 V   Starting method 24V DC electric start
Rated speed 1000rpm   Voltage regulation Automatic
Rated frequency 50Hz   Cooling Mode Close type water cool
Rated current 2164A   Heat Consumption 10200kJ/kWh
Power factor 0.8 Lagging   Dimension (mm) 6583x2180x2540mm
Control mode Electric control   Net Weight (kg) 24000

MAIN ELECTRICAL PERFORMANCE OF THE GAS GENERATOR
Voltage
Stabilized regulation Instantaneous regulation Recovery time Fluctuation
±2.5% +20% - 15% 1.5S 0.5%
Frequency
Stabilized regulation Instantaneous regulation Recovery time Fluctuation
0-5% adjustable +10%,-10% < 7 S 0.5%

MAIN SPECIFICATIONS OF GAS ENGINE
Model H16V190ZLT-2
Rated power 1320kW (1650KVA)
Number and layout of cylinders: 16-cylinders, V-type, 60° included angle
Type Four strokes, Closed type water cooled, Turbo-charged, Electronic ignition, Electronic speed governor
Ignition type Spark plug ignition
Intake gas pressure required 100-400 kPa before gas pressure regulator
Bore´Stroke 190´215 mm
Speed Governor (Woodward) EGS-02 Electric governor
Oil consumption £ 0.8g/kWh
Total lubricating oil capacity (Liters) 460L
Exhaust temperature (before turbine) £ 680 °C
Heavy overhauling period 36,000h
















MAIN SPECIFICATIONS OF ALTERNATOR
Alternator model Exciting model Insulation class Connection Cooling Structure type
1FC6564-6LA42 (SIEMENS) Brushless Class F 3-phase, 4-wire Air cooled AVR and reactive droop regulator assembled in alternator
 
(Kindly Noted: data shown in above table tested under standard working condition: 25 Dec C, atmospheric pressure 100kPa, relative humidity 30%, altitude <1000m.)

CONTROL PANEL

Control panel is panel type, vertical structure, model is GPL1200. Control panel is equipped with meters showing various parameters of operating status, automatic air switch and timer. All of the electric cells possess three-proof functions.

The Generator possesses the following automatic monitoring and protective functions

A) Audio or visual alarm for:
-   High oil and water temperature
-   Low oil pressure
-   Over current
-   Short circuit
-   Over-speed
-   Reverse power
B) Shut-off for:
-   Low oil pressure
-   Over-speed
-   Short circuit
-   Over-speed
-   Reverse power
C) Trip-off for:
-   Over-current
-   Short circuit
-   Reverse power
The generator can not only supply power directly to load but also can be paralleled running.

OPTIONAL DEVICE
♦ Steel Soundproof Container (sound attenuated canopy)
♦ CHP/ Cogeneration/CCHP Trigeneration
♦ ATS and Synchronization Parallelling Panel
♦ Oil and Water Heater
 